Bismuth shielding in computed tomography
WebDec 3, 2009 · In this research, using direct measurements and Monte Carlo calculations, the potential dose reduction achieved by bismuth shielding in computed tomography was evaluated. The patient dose was measured using an ionisation chamber in a polymethylmethacrylate (PMMA) phantom that had five measurement points at the … WebApr 11, 2012 · Bismuth shielding increases image noise across the entire image, not just directly under the shields. 3–5 It also causes streak and beam hardening artifacts, which can artifactually increase CT numbers, …
Bismuth shielding in computed tomography
Did you know?
WebJun 25, 2024 · Bismuth shielding techniques have been used to reduce radiation, but image noise increased, degrading image quality. Purpose: The aim of this study was to investigate how the use of iterative reconstruction (IR) combined with bismuth shielding influences image quality. Materials and methods: WebApr 1, 2024 · In this research, using direct measurements and Monte Carlo calculations, the potential dose reduction achieved by bismuth shielding in computed tomography was evaluated. The patient dose was ...
WebDec 1, 2024 · The literature indicates that bismuth shielding increases image noise and CT numbers as well as introducing streak artifacts. Tube current modulation (TCM) technique and iterative reconstruction algorithms can provide some levels of dose reduction to radiosensitive organs and superior image quality without the disadvantages of bismuth … WebConclusion: Until these alternative methods become available in all departments, bismuth shielding remains a viable dose reduction strategy. KEY WORDS: Computed …
WebApr 23, 2024 · This research work aims to investigate the radiation shielding ability of a Yb 3+-doped calcium borotellurite glass system.The system has the basic composition of CaF 2 –CaO–B 2 O 3 –TeO 2 –Yb 2 O 3 but is denoted as TeBYbn for simplicity. The effect of increasing the TeO 2 content in the glasses from 10 to 54 mol% was investigated, with … Web6 rows · Jun 25, 2024 · Bismuth shielding techniques have been used to reduce radiation, but image noise increased, ...
WebMay 30, 2024 · Computed Tomography (CT) has become an important tool to diagnose cancer and to obtain additional information for different clinical questions. Today, it is a very fast, painless and noninvasive test that can be performed high quality images. ... Evaluation in the Use of Bismuth Shielding on Cervical CT Scan Using a Female Phantom
WebINIS Repository Search provides online access to one of the world's largest collections on the peaceful uses of nuclear science and technology. The International Nuclear Information System is operated by the IAEA in collaboration with over 150 members. dfw rv campingWebBackground: Coronary computed tomographic angiography (CCTA) is associated with high radiation dose to the female breasts. Bismuth breast shielding offers the potential to significantly reduce dose to the breasts and nearby organs, but the magnitude of this reduction and its impact on image quality and radiation dose have not been evaluated. chymes dreaming mp3 downloadWebJan 1, 2012 · Organ-based TCM provided superior image quality to that with bismuth shielding while similarly reducing dose to the eye. Simply reducing tube current globally by about 30% provides the same dose … chymes artistWebBismuth shielding was recommended in 88.89% of the studies based on the maintenance of appropriate image quality under shielding. Noise associated with Bi shielding was 7.5%, 263%, and 23.5% for the eye, thyroid, and breast, respectively. dfw rv dealershipsWebBismuth shielding has been used to reduce the dose from CT to anterior radiosensitive organs, such as the breast, lens of the eye, thyroid, and gonads [1,2]. ... Cantera A: Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality. Eur Radiol 2006, … chymes gurney room for rentWebBackground: To quantify image quality and radiation doses in regions adjacent to and distant from bismuth shields in computed tomography (CT). Methods: An American College of Radiology accreditation phantom with four solid rods embedded in a water-like background was scanned to verify CT number (CTN) accuracy when using bismuth shields. chyme small intestineWebBackground: Although the bismuth breast shield can reduce radiation exposure to the breast during dual-energy computed tomography (DECT), it can potentially affect material quantification on DECT due to artifacts. Purpose: To evaluate the effects of bismuth breast shielding on iodine quantification and radiation exposure in DECT. chymeric hydra stem cells